Falcon Technologies KSA
Diesel / Fuel Tanks — Falcon Technologies
HomeDiesel / Fuel Tanks

Tank Solutions

Diesel / Fuel Tanks

Generator diesel tanks, underground diesel tanks and industrial fuel storage in steel or FRP/GRP.

Tank Solutions

Diesel and Fuel Tanks for Industrial and Commercial Sites

Reliable fuel storage keeps generators, plant and fleets running. Falcon supplies diesel and fuel tanks for generator sets, underground installations and larger industrial storage, in steel or FRP/GRP depending on capacity, location and specification.

Fuel storage is governed by client and regulatory requirements, so tank design, fittings and installation details are confirmed against your project specification before fabrication.

Diesel / Fuel Tanks by Falcon Technologies in Saudi Arabia
Tank Solutions

What We Offer

Generator diesel tanks

Tanks sized and fitted for generator sets and standby power.

Underground diesel tanks

Buried tanks with anchoring, foundation and installation details.

Aboveground fuel tanks

Aboveground storage for site and industrial fuel supply.

Industrial fuel storage

Larger fuel storage fabricated to the project specification.

Skids and supports

Supports and skid arrangements fabricated with the tank.

Inspection and leak testing

Checks and testing as applicable before delivery.

Technical Snapshot

Tank types
Generator diesel tanks, underground diesel tanks, aboveground fuel tanks, industrial fuel storage
Materials
Steel or FRP/GRP, chosen per application
Fittings
Nozzles, manholes, vents and level connections per drawing
Installation
Aboveground, underground or skid-mounted where suitable
Testing
Leak and hydrostatic testing where applicable
Requirements
Built to client, project and applicable regulatory specifications

Where It’s Used

Power & utilitiesOil & gasManufacturing plantsConstruction & infrastructureCommercial & industrial buildings

From Duty Review to Delivery

  1. 01

    Confirm capacity and duty

    Fuel type, volume, location and requirements.

  2. 02

    Engineer and specify

    Material, fittings and drawings agreed before fabrication.

  3. 03

    Fabricate and inspect

    Built and inspected to the approved drawing.

  4. 04

    Test and deliver

    Leak or hydrostatic testing as applicable, then documented delivery.

Reference Sizes

Documented configurations we can reference as a starting point — confirmed per project, not a committed availability.

Underground diesel (FRP)
20,000 L — Ø2,500 mm × 4,350 mm long; 30,000 L — Ø2,500 mm × 6,400 mm long.

Indicative reference configurations from prior project and design context — not a committed catalogue range or current availability. Final capacity and dimensions are confirmed against the approved drawing and QA file for each project.

Standards & Compliance

UL 142
Steel aboveground tanks for flammable/combustible liquids — listing applies to the exact model.
UL 58
Steel underground tanks for flammable/combustible liquids.
UL 1316
Fibre-reinforced underground tanks for flammable/combustible liquids.
API 650
Welded oil-storage tanks within scope — not a substitute for UST product listings.
ISO 28300
Venting of atmospheric and low-pressure petroleum storage tanks — confirm current edition and project basis.

A standard reference is not proof of third-party certification. Falcon states “designed and manufactured to” a standard only when it is backed by the controlled design and QA file; chemical, potable-water and underground suitability require separate product-specific evidence. Saudi/GCC approvals (SASO/SABER, Civil Defense, environmental, municipal, utility and owner approvals) are project- and product-specific.

Accessories & Fittings

Access / manwayInlet / outletOverflowVentDrainLevel gauge / transmitterLadder, platform & handrailsLifting lugsHold-downs / anchorsBafflesSample pointInstrument portsPump / filter / skidLeak monitoringGrounding / instrumentationInterstitial monitoring (double-wall)

Nozzle size, material, reinforcement and orientation are set in the nozzle schedule for each tank. Accessories are fitted as the service requires.

Frequently Asked Questions

Should a diesel tank be steel or FRP?

Both are used. Steel is common for larger and higher-load fuel storage; FRP/GRP offers corrosion resistance, particularly underground. We recommend based on capacity, location and specification.

Do you supply underground diesel tanks?

Yes. Underground diesel tanks are available with the anchoring, foundation and installation details needed for the ground conditions.

Can you make a tank for a generator set?

Yes. Generator diesel tanks are part of our scope and are sized and fitted to the generator and site requirement.

Falcon Technologies industrial tank and service facility
Let's Work Together

Ready to Start Your Next Project?

Get in touch with our engineering team for a free consultation and a tailored proposal for your site.